  1.     SECTION 10530
  2.  
  3.     PROTECTIVE COVERS
  4. NOTE ** Allmet Building Products, Inc. awning and canopy systems.
  5. NOTE ** 
  6. NOTE ** This section is based on protective cover systems manufactured by Allmet Building Products, Inc., at the following address:
  7. NOTE **     227 South Town East Boulevard
  8. NOTE **     Mesquite TX 75149
  9. NOTE **     P.O. Box 850163, Mesquite TX 75185-0163
  10. NOTE **     Tel:  (972) 285-8811
  11. NOTE **     Fax:  (800) 998-2898
  12. NOTE **     Fax:  (972) 882-8818 
  13. NOTE ** 
  14. NOTE ** Allmet Building Products, Inc. offers a complete line of awning and canopy systems.
  15. NOTE ** 
  16. NOTE ** SECTION 10530 - PROTECTIVE COVERS, Copyright 1998, The Architect's Catalog, Inc. 
  17.  
  18. PART 1    GENERAL
  19.  
  20. 1.1    SECTION INCLUDES
  21. NOTE ** Delete items below not required for project.
  22.  
  23.     A.    Commercial Awning System.
  24.  
  25.     B.    Building Facing System.
  26.  
  27.     C.    Canopy System.
  28.  
  29. 1.2    RELATED SECTIONS
  30. NOTE ** Delete sections below not relevant to this project; add others as required.
  31.  
  32.     A.    Section 03300 - Cast-In-Place Concrete.
  33.  
  34.     B.    Section 03410 - Structural Precast Concrete.
  35.  
  36.     C.    Section 04810 - Unit Masonry Assemblies.
  37.  
  38.     D.    Section 05400 - Cold-Formed Metal Framing.
  39.  
  40. 1.3    REFERENCES
  41. NOTE ** Delete references from the list below that are not actually required by the text of the edited section.
  42.  
  43.     A.    AA  ADM-1-516166 - Aluminum Design Manual; Aluminum Association.
  44.  
  45.     B.    AAMA 605.2 - Voluntary Specification for High Performance Coatings on Architectural Extrusions and Panels.
  46.  
  47.     C.    AAMA 607.1 - Voluntary Specification and Inspection Methods for Clear Anodic Finishes for Architectural Aluminum.
  48.  
  49.     D.    ASTM A 500 - Standard Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes.
  50.  
  51.     E.    ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
  52.  
  53.     F.    ASTM B 117 - Standard Method of Salt Spray (Fog) Testing.
  54.  
  55.     G.    ASTM B 209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate.
  56.  
  57.     H.    ASTM B 221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes.
  58.  
  59.     I.    ASTM D 1735 - Standard Practice for Testing Water Resistance of Coating Using Water Fog Apparatus.
  60.  
  61.     J.    ASTM D 2244 - Standard Test Method for Calculation of Color Differences from Instrumentally Measured Color Coordinates.
  62.  
  63.     K.    ASTM D 4214 - Standard Test Method for Evaluating the Degree of Chalking of Exterior Paint Films.
  64.  
  65.     L.    ASTM G 87 - Standard Practice for Conducting Moist Sulfur Dioxide Tests.
  66.  
  67. 1.4    SYSTEM DESCRIPTION
  68. NOTE ** Insert loading requirements into the following paragraph.
  69.  
  70.     A.    Systems specified in this section to support live load of ______ pounds per square foot, plus weight of system, and to resist wind uplift of _______ pounds per square foot.
  71.  
  72. 1.5    SUBMITTALS
  73.  
  74.     A.    Submit under provisions of Section 01300.
  75.  
  76.     B.    Product Data:  Manufacturer's descriptive literature for specified systems, including all components.
  77.  
  78.     C.    Shop Drawings:  Indicate layouts heights, component connection details, and details of interface with adjacent construction.
  79. NOTE ** Delete the following paragraph if specifying custom colors or finishes.
  80.  
  81.     D.    Selection Samples:  Two sets of color chips representing manufacturer's full range of available colors.
  82.  
  83.     E.    Verification Samples:  Two samples, minimum size 6 inches square, representing actual color and finish of products to be installed.
  84.  
  85.     F.    Design Data:  Computed in accordance with AA "Aluminum Design Manual" for performance requirements specified in SYSTEM DESCRIPTION Article of PART 1 of this section, bearing seal and signature of registered professional Structural Engineer licensed to practice in the State in which the Project is located.
  86.  
  87.     G.    Certificates:
  88.         1.    Contractor's certification that manufacturer of products of this section meet specified qualifications.
  89.         2.    Manufacturer's certification that installer of this section is approved.
  90.  
  91.     H.    Manufacturer's printed installation instructions for specified systems, including each component.
  92.  
  93.     I.    Closeout Submittals:  Warranty documents, issued and executed by manufacturer, countersigned by Contractor.
  94.  
  95. 1.6    QUALITY ASSURANCE
  96.  
  97.     A.    Manufacturer Qualifications:  Minimum five (5) years documented experience producing systems specified in this section.
  98.  
  99.     B.    Installer Qualifications:  Minimum three (3) years documented experience installing systems specified in this section, and approved by manufacturer.
  100.  
  101.     C.    Regulatory Requirements:  Comply with requirements of building authorities having jurisdiction in Project location.
  102. NOTE ** Delete the following paragraph if not required.
  103.  
  104.     D.    Pre-Installation Meeting:
  105.         1.    Convene at job site seven (7) calendar days prior to scheduled beginning of construction activities of this section to review requirements of this section.
  106.         2.    Require attendance by representatives of the installer and other entities directly affecting, or affected by, construction activities of this section.
  107.         3.    Notify Architect four (4) calendar days in advance of scheduled meeting date.
  108.  
  109. 1.7    DELIVERY, STORAGE, AND HANDLING
  110.  
  111.     A.    Store system components in accordance with manufacturer's instructions until installation.
  112.  
  113. 1.8    WARRANTY
  114.  
  115.     A.    Furnish systems manufacturer's standard warranty against defects in product workmanship and materials, including deterioration of metal finishes.
  116.  
  117.  
  118. PART 2    PRODUCTS
  119.  
  120. 2.1    MANUFACTURERS
  121.  
  122.     A.    Acceptable Manufacturer:  Allmet Building Products, Inc.; 227 South Town East Boulevard, Mesquite TX 75149; P.O. Box 850163, Mesquite TX 75185-0163; ASD. Tel: (972) 285-8811, Fax: (800) 998-2898 or (972) 882-8818.
  123. NOTE ** Delete one of the two following paragraphs; coordinate with Division 01 requirements. 
  124.  
  125.     B.    Requests for substitutions will be considered in accordance with provisions of Section 01600.
  126.  
  127.     C.    Substitutions:   Not permitted.
  128. NOTE ** Delete following paragraph if substitutions not permitted. 
  129.  
  130.     D.    Unless otherwise specified for an individual product or material, supply all products specified in this section from the same manufacturer.
  131.  
  132. 2.2    COMMERCIAL AWNING SYSTEM
  133.  
  134.     A.    Acceptable System:  Allmet Commercial Awning System.
  135. NOTE ** Retain one of the following two paragraphs to specify face panel type required.
  136.  
  137.     B.    Face Panels:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.025 inch sheet thickness, 3-5/16 inches wide; factory formed long edges rolled to 5/16 inch radius.
  138.  
  139.     C.    Face Panels:
  140.         1.    Material:  Translucent acrylic sheet, 0.025 inch sheet thickness, 3-5/16 inches wide; factory formed long edges rolled to 5/16 inch radius.
  141. NOTE ** Determine method of color selection; retain one of following three paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain third paragraph below and coordinate with SCHEDULES Article of Part 3.
  142.         2.    Color:  Selected from full range of manufacturer's standard colors.
  143.         3.    Color:  _________________.
  144.         4.    Color:  Specified in SCHEDULES Article of this section.
  145. NOTE ** Retain one of the following four paragraphs to specify stringer type required.
  146.  
  147.     D.    Stringers:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.040 inch sheet thickness; formed for snap-in ventilated installation of face panels.
  148.  
  149.     E.    Stringers:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.040 inch sheet thickness; formed for snap-in sealed installation of face panels.
  150.  
  151.     F.    Stringers:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.040 inch sheet thickness; formed for snap-in open-louver installation of face panels.
  152.  
  153.     G.    Stringers:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.040 inch sheet thickness; formed for snap-in closed-louver installation of face panels.
  154. NOTE ** Delete the following paragraph if soffit panels not required.
  155.  
  156.     H.    Soffit Panels:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.032 inch sheet thickness; formed to 6-inch wide flat profile.
  157.  
  158.     I.    Structural Components:
  159.         1.    Steel components:  Steel sheet conforming to ASTM A 653/A 653M, commercial quality, 0.040 inch sheet thickness, galvanized to G90/Z725 coating.
  160.         2.    Aluminum components:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.040 inch sheet thickness.
  161.         3.    Mounting brackets:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.080 inch sheet thickness.
  162.         4.    Fasteners:  Non-corrodible, or having non-corrodible finish.
  163.  
  164.     J.    Finish:  Baked-on polyester coating, conforming to AAMA 605.2, applied prior to fabrication, except as indicated otherwise; materials for components shall receive chemical cleaning, conversion coating, and baked-on primer coating prior to application of finish coat.
  165.         1.    High Acid Salt Spray (HASS) Test, conducted in accordance with ASTM B 117:  500 hours.
  166.         2.    Humidity resistance test, conducted in accordance with ASTM D 1735:  500 hours.
  167.         3.    Sulfur dioxide test, conducted in accordance with ASTM G 87:  500 hours.
  168.         4.    Weathering, color retention/chalk test; Dew Cycle Weatherometer test of 300 hours:  Chalking not in excess of 8 when rated in accordance with ASTM D 4214; color change not in excess of 7E Hunter units when rated in accordance with ASTM D 2244.
  169.         5.    Boiling water test:  No lifting, discoloration, or blistering after 7 hours; no lifting or discoloration after 72 hours.
  170.  
  171.     K.    Colors:
  172. NOTE ** Determine method of color selection; retain applicable following sub-paragraphs, or delete all and retain one of the following two paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain sub-paragraph below and coordinate with SCHEDULE Article of PART 3.
  173.         1.    Face panels:  Manufacturer's standard color _____________.
  174.         2.    Face panels:  Custom color _____________.
  175.         3.    Soffit panels and structural components:  Manufacturer's standard color _____________.
  176.         4.    Soffit panels and structural components:  Custom color _____________.
  177.  
  178.     L.    Colors:  Selected from manufacturer's full range of available colors.
  179.  
  180.     M.    Colors:  Specified in SCHEDULE Article of PART 3 of this section.
  181.  
  182. 2.3    BUILDING FACING SYSTEM
  183.  
  184.     A.    Face Panels:
  185.         1.    Material:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.025 inch sheet thickness, 3-5/16 inches wide; factory formed long edges rolled to 5/16 inch radius.
  186. NOTE ** Determine method of color selection; retain one of following three paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain third paragraph below and coordinate with SCHEDULES Article of Part 3.
  187.         2.    Color:  Selected from full range of manufacturer's standard colors.
  188.         3.    Color:  _________________.
  189.         4.    Color:  Specified in SCHEDULES Article of this section.
  190. NOTE ** Retain one of the following four paragraphs to specify stringer type required. 
  191.  
  192.     B.    Stringers:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.040 inch sheet thickness; formed for snap-in ventilated installation of face panels.
  193.  
  194.     C.    Stringers:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.040 inch sheet thickness; formed for snap-in sealed installation of face panels.
  195.  
  196.     D.    Stringers:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.040 inch sheet thickness; formed for snap-in open-louver installation of face panels.
  197.  
  198.     E.    Stringers:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.040 inch sheet thickness; formed for snap-in closed-louver installation of face panels.
  199. NOTE ** Delete the following paragraph if soffit panels not required.
  200.  
  201.     F.    Soffit Panels:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, 0.032 inch sheet thickness; factory finished and formed to 6-inch wide flat profile.
  202.  
  203.     G.    Fasteners:  Non-corrodible, or having non-corrodible finish; type specified in manufacturer's installation instructions for project conditions.
  204.  
  205.     H.    Finish:  Baked-on polyester coating, conforming to AAMA 605.2, applied prior to fabrication, except as indicated otherwise; materials for components shall receive chemical cleaning, conversion coating, and baked-on primer coating prior to application of finish coat.
  206. NOTE ** Determine method of color selection; retain applicable following sub-paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain last sub-paragraph below and coordinate with SCHEDULE Article of PART 3.
  207.         1.    Face panels:  Manufacturer's standard color _____________.
  208.         2.    Face panels:  Custom color _____________.
  209.         3.    Soffit panels and structural components:  Manufacturer's standard color _____________.
  210.         4.    Soffit panels and structural components:  Custom color _____________.
  211.         5.    Colors:  Selected from manufacturer's full range of available colors.
  212.         6.    Colors:  Specified in SCHEDULE Article of PART 3 of this section.
  213.  
  214. 2.4    CANOPY SYSTEM
  215.  
  216.     A.    Acceptable System:  Allmet Canopy System.
  217. NOTE ** Delete roof panel types not required.
  218.  
  219.     B.    Roof Panels:  Allmet Twin-Vee Panel.
  220. NOTE ** Retain one of the following two sub-paragraphs to specify material required for project. 
  221.         1.    Material:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28 or alloy 3004-H36.
  222.         2.    Material:  Galvanized steel sheet conforming to ASTM A 653/A 653M, G90/Z725 coating, cold-rolled, commercial quality.
  223.         3.    Sheet thickness:  In accordance with design data for specified performance requirements.
  224.         4.    Profile:  Twin V-profile with longitudinal ribs at ridges, 12-inch panel width, 2.50 inches profile height; long edges formed to interlock with adjacent panels.
  225.  
  226.     C.    Roof Panels:  Allmet Grand Prix Panel.
  227. NOTE ** Retain one of the following two sub-paragraphs to specify material required for project. 
  228.         1.    Material:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28.
  229.         2.    Material:  Galvanized steel sheet conforming to ASTM A 653/A 653M, G90/Z725 coating, cold-rolled, commercial quality.
  230.         3.    Sheet thickness:  In accordance with design data for specified performance requirements.
  231.         4.    Profile:  Flat pan profile, 12-inch panel width, 2.50 inches profile height; long edges formed to interlock with adjacent panels.
  232.  
  233.     D.    Roof Panels:  Allmet 8-Inch Flat Panel.
  234. NOTE ** Retain one of the following two sub-paragraphs to specify material required for project. 
  235.         1.    Material:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28.
  236.         2.    Material:  Galvanized steel sheet conforming to ASTM A 653/A 653M, G90/Z725 coating, cold-rolled, commercial quality.
  237.         3.    Sheet thickness:  In accordance with design data for specified performance requirements.
  238.         4.    Profile:  Flat pan profile with longitudinal ribs at center of pan, 8-inch panel width, 2.50 inches profile height; with long edges formed to interlock with adjacent panels.
  239. NOTE ** Delete fascia type not required for project in the following two paragraphs. 
  240.  
  241.     E.    Fascia:  Allmet 6-1/2 Inch R-F Fascia.
  242.         1.    Material:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28.
  243.         2.    Sheet thickness:  0.050 inch.
  244.         3.    Profile:  Box profile with two continuous horizontal recesses in face, integral gutter, 6.33 inches profile height, 3.25 inches gutter width.
  245.  
  246.     F.    Fascia:  Allmet 6-Inch Extruded Fascia.
  247.         1.    Material:  Extruded aluminum conforming to ASTM B 221, alloy 6063-T6.
  248.         2.    Extrusion wall thickness:  0.080 inch.
  249.         3.    Profile:  Box profile with two longitudinal recessed channels in face for installation of decorative trim, integral gutter, 6.00 inches profile height, 3.44 inches gutter width.
  250. NOTE ** Delete one of the following two paragraphs; first is for formed fascia, second is for extruded fascia. 
  251.  
  252.     G.    Fascia Corner Sections:  Manufacturer's standard for indicated fascia, of same material, sheet thickness, and finish as fascia; factory-fabricated and heliarc-welded, with smooth hairline miter seams.
  253.  
  254.     H.    Fascia Corner Sections:  Same material, profile, extrusion wall thickness, and finish as fascia; factory-fabricated and heliarc-welded, with smooth hairline miter seams.
  255. NOTE ** Delete the following paragraph if not required for project; if retained, select profile required for project. 
  256.  
  257.     I.    Wall Panels:  Allmet Decor Wall Panel.
  258.         1.    Material:  Aluminum sheet conforming to ASTM B 209, alloy 3005-H28, sheet thickness 0.032 inch; formed 6 inches wide by 3/4 inch projection, with long edges formed to interlock with adjacent panels.
  259.         2.    Profile:  Concave.
  260.         3.    Profile:  Convex.
  261.         4.    Profile:  Flat.
  262.  
  263.     J.    I-Beams, C-Beams, and Box Beams:
  264.         1.    Material:  Extruded aluminum conforming to ASTM B 221, alloy 6061-T6 or alloy 6063-T6.
  265.         2.    Profiles and structural properties:  In accordance with design data for specified performance requirements.
  266. NOTE ** Delete the following paragraph if not required for project; if retained, select material required for project. 
  267.  
  268.     K.    Formed Sheet Metal Tubes:
  269.         1.    Material:  Aluminum sheet conforming to ASTM B 209, alloy 3004-H36; sheet thickness:  0.050 inch.
  270.         2.    Material:  Galvanized steel sheet conforming to ASTM A 653/A 653M, G90/Z725 coating, cold-rolled, commercial quality; sheet thickness 0.050 inch.
  271.         3.    Profile:  3-inch diameter tube.
  272. NOTE ** Delete the following paragraph specifying extruded aluminum columns if not required for project. 
  273.  
  274.     L.    Posts:
  275.         1.    Material:  Extruded aluminum conforming to ASTM B 221, alloy 6063-T6.
  276.         2.    Structural properties:  In accordance with design data for specified performance requirements.
  277. NOTE ** Retain one of the following three sub-paragraphs for required profile and size. 
  278.         3.    Profile:  3-inch by 3-inch, smooth.
  279.         4.    Profile:  3-inch by 3-inch, fluted.
  280.         5.    Profile:  4-inch by 4-inch, smooth.
  281. NOTE ** Delete the following paragraph specifying heavy duty pipe columns if not required for project. 
  282.  
  283.     M.    Posts:
  284.         1.    Material:  Seamless or welded steel tube conforming to ASTM A 500.
  285.         2.    Profiles and structural properties:  In accordance with design data for specified performance requirements.
  286. NOTE ** Delete the following paragraph if overhead support is not required for the project. 
  287.  
  288.     N.    Overhead Support Assembly:  Struts of 2 inch by 2 inch extruded aluminum tube conforming to ASTM B 221, alloy 6063-T6, with brackets, couplings, and connectors of same material, sized in accordance with design data for specified performance requirements; components clear anodized to conform to AAMA 607.1, R204R1.
  289.  
  290.     O.    Fasteners and Connectors:  Brackets, clip angles, bolts, nuts, washers, and other items indicated in approved shop drawings or required in design data; bolts, nuts, washer, and other fasteners to be non-corrodible material or to have non-corrodible finish.
  291.  
  292.     P.    Finish:  Baked-on polyester coating, conforming to AAMA 605.2, applied prior to fabrication, except as indicated otherwise; materials for components shall receive chemical cleaning, conversion coating, and baked-on primer coating prior to application of finish coat.
  293. NOTE ** Determine method of color selection; retain applicable following sub-paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain last sub-paragraph below and coordinate with SCHEDULE Article of PART 3. 
  294.  
  295.         1.    Roof panels:  Manufacturer's standard color _____________.
  296.         2.    Roof panels:  Custom color _____________.
  297.         3.    Wall panels:  Manufacturer's standard color _____________.
  298.         4.    Wall panels:  Custom color _____________.
  299.         5.    Fascia panels and structural components:  Manufacturer's standard color _____________.
  300.         6.    Fascia panels and structural components:  Custom color _____________.
  301.         7.    Colors:  Selected from manufacturer's full range of available colors.
  302.         8.    Colors:  Specified in SCHEDULE Article of PART 3 of this section.
  303.  
  304.  
  305. PART 3    EXECUTION
  306.  
  307. 3.1    EXAMINATION
  308.  
  309.     A.    Verify that project conditions are as indicated on shop drawings.
  310.  
  311.     B.    Installer's Examination:
  312.         1.    Have installer of this section examine conditions under which construction activities of this section are to be performed, then submit written notification if such conditions are unacceptable.
  313.         2.    Transmit two copies of installer's report to Architect within 24 hours of receipt.
  314.         3.    Beginning construction activities of this section before unacceptable conditions have been corrected is prohibited.
  315.         4.    Beginning construction activities of this section indicates installer's acceptance of conditions.
  316.  
  317. 3.2    PREPARATION
  318.  
  319.     A.    Ensure that adjacent surfaces, structures, and finishes are protected from damage by construction activities of this section.
  320.  
  321. 3.3    INSTALLATION
  322.  
  323.     A.    Install systems specified in this section in accordance with shop drawings and manufacturer's installation instructions.
  324. NOTE ** Delete the following paragraph if posts not required. 
  325.  
  326.     B.    Placing of concrete for post bases is specified in Section 03300.
  327.  
  328. 3.4    CLEANING
  329.  
  330.     A.    Remove dust or other foreign matter from component surfaces; clean finishes in accordance with manufacturer's instructions.
  331.  
  332. 3.5    PROTECTION OF INSTALLED PRODUCTS
  333.  
  334.     A.    Ensure that finishes and structure of installed systems are not damaged by subsequent construction activities.
  335.  
  336.     B.    If minor damage to finishes occurs, repair damage in accordance with manufacturer's recommendations; provide replacement components if repaired finishes are unacceptable to Architect.
  337. NOTE ** If more than one system or color is required for project, the following sample schedule will locate type and color selections for the systems specified; delete Article if not required. 
  338.  
  339. 3.6    SCHEDULE 
  340.  
  341.     A.    Awning Number __:  Allmet Commercial Awning.
  342.         Location:  Employee Entrance.
  343.         Face panels:  Color _______________.
  344.         Soffit panels:  Color _______________.
  345.         Wall facing panels above awning:  Match color of awning.
  346.  
  347.     B.    Canopy Number __:  Allmet Canopy System.
  348.         Location:  Loading Dock, Walkway Covers, Carports, Canopies.
  349.         Roof panels:  Color white.
  350.         Fascia:  Color dark bronze.
  351.         Posts:  Match color of fascia.
  352.  
  353.  
  354.     END OF SECTION